6. Trouble Shooting
Before using the product, please be sure that Power LED is on. If the Power LED is not on, please
check the following steps:
1. Check if the mains is normal.
2. Check if the power cord is connected firmly.
3. Check if the connected devices are connected to the unit firmly.
4. Check if the unit is turned on.
Problem
Possible Cause
Solutions
Circuit breaker is

The unit is overload.
Remove some loads first. Reset the circuit
breaker by pressing the button again.
The unit is turned off
automatically and the
Power LED is not lit.
The unit is over-
internal protected function.
Remove some loads and wait until the unit
is cool. Then turn on the unit again.
7. Specifications
AVR 600
AVR 1000
AVR 1200
600VA / 360W
1000VA / 600W
1200VA / 720W
220VAC
180 - 264VAC
50Hz
+/-12%
+/-8%
INDICATOR
Green lighting
Red lighting
Short circuit, overload, and over-temperature protection
PHYSICAL
166mm x 161mm x 86.7mm
1.7
2.0
2.1
Environment
0-90% RH @ 0-40° C (non-condensing)
Less than 40dB
EN